Due to physical access requirements, a customer has determined the HMC must be moved to a secure location that exceeds the 15 meter limit by 200 meters. What is the only supported method to provide this extended distance connection?
Answer(s)
- Use the current 8-port Async adapter and replace the 15 meter cable with a compatible OEM cable of the required length.
- Replace the 8-port Async adapter and 15 meter cable with the 128-port Async adapter compatible OEM RS422 cable of the required length.
- Replace the 8-port Async adapter with the 128-port Async adapter, compatible OEM RS422 cable of the required length, Remote Async Node (RAN), and RJ45 to DB25 converter cable.
- Replace the 8-port Async adapter and 15 meter cable with the 128-port Async adapter, Remote Async Node (ran), rj45 TO db25 CONVERTER CABLE, AND COMPATIBLE oem rs422 CABLE OF THE REQUIRED LENGTH.